R-15
Product characteristics
High precision: The cable defect positioning results are accurate and reliable, with an error less than 0.1%.
Fast detection: The detection speed is fast, no damage to the cable, can shorten the power outagemaintenance time, and minimize the impact of power outage.
Test without blind spot: The device can locate short cable faults and defects without test blind spots and can test the fault of unarmored cables, with better field applicability.
Light and portable: Using linear cable parameters, dielectric constant impedance measuremen support three-phase test and the same screen comparison.
Product function
R-15 cable wideband impedance analyzer can locate faults in power cables and communication cables of any voltage level, such as over-short circuit (trip) break (power off),partial discharge (spark)
It can also locate cable defects, such as local thermal aging, water moisture, overheating, radiation, wa
ter tree intrusion, electric tree intrusion, external damage、cable breakdown.
The fault types of motor winding (inter-turn short circuit,winding loosening, local thermal aging, end creepage,fracture of pressure equalizing coating, etc.) can be judged
analyte
Dc cables, armless cables, communication cables, 380V, 6KV,10KV, 35KV, 110KV, 220kV, 550kV power cables; Motor winding.
test mode
Low voltage pulse method TDR, low voltage pulse comparison method, RTDR enhanced pulse test and FDR spectrum test. Optional: arc reflection Method ARM, Active arc radiation method Act ive ARM, three pulse method ARM Plus, pulse current method ICE, Decay Method, arc reflection arc Burning method ARM Burning.
The test value depends on the capacitance and quality factors at the test frequency, inductance,resistance, dissipation factor at all frequencies.
The product key has a unique device activation code, and the password menu operator can log in without an administrator.
Accurately test the map of cable length and intermediate joint position, and the characteristic waveforms need to respond to impedance changes at different rates of change.
Zero phase compensation function, dynamic bandwidth, characteristic quantity and polarity check positioning Typical spectrum of periodic attenuation oscillations at high frequency an dultra-high frequency.
Cable defect simulation function; The software comes with database management function, which can classify and manage the test data.
Technical parameter
Test parameter
Test frequency band range: 20Hz ~ 1 00MH
Dynamic range and tail correction: 115dB+40dB
Maximum voltage output of excitation source:0.2~20Pk-pk , update rate 1000MS/s
Defect location error <= 0.5%
Positioning accuracy 0.1%.
Resolution filter 0.1 m @ v/2 80 m/μs,1 cm @ v/2 < 40 m/μs, 20 –50m ,4500 kHz, 2100 kHz, 1000 kHz, 450 kHz, 250 kHz
Time base accuracy < 50 ppm (0.005%)
Effective test length 1 0m~300km Maximum range:1280km(当v/2=80 m / μs)
pulse 30—160V;Pulse width(S):20ns…10μs Maximum range 250 ns … 16 ms
Acceptable operating temperature -20℃~ +60℃
Acceptable working humidity ≤ 80% (RH, Relative humidity)
Workable altitude ≤ 3 000m
Automatically match the output impedance 10Ω…2000Ω
Mechanical parameter
weight 3.2kg
dimension 2 2 × 20 × 8cm
Power DC, 9~24V, 1 0W
attachments DC power cable, USB data transmission cable, alligator
clamp connection cable for cable connection, sturdy